Product Details:
|
Multi - Parameter: | ECG, NIBP, SPO2, TEMP, RESP, Printer (Optional) | Screen: | 12.1" High Resolution Color TFT LCD Display |
---|---|---|---|
Weight: | 5kg | Applicant: | Various Pet Clinics, Pet Hospitals, Veterinary Stations And Zoos |
Safty Standard: | GB9706.1 | Animal Accessories: | Animal ECG Clip Type Cable, Animal Blood Pressure Cuffs, Animal Blood Oxygen Probe |
Highlight: | multiparameter patient monitor,patient monitoring systems |
5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices
Specification
1 | ECG | Lead selection: full lead, Ⅰ, Ⅱ, Ⅲ, aVF, aVR, aVL, V1-6 chest lead display Gain selection: ×1, ×2, ×0.25, ×0.5 four gears Frequency: 0.5Hz—100Hz Common mode signal rejection: greater than 70dB Scanning speed: 12.5mm/s, 25mm/s, 50mm/s three standard files Heart rate accuracy: ±5 beats/minute Calibration signal: 1mV (peak value, accuracy ±3%) ST segment detection: measuring range (-2.0mV---+2.0mV) Use standard: in line with ANSI/AMI EC13-2002 standard Response time: 1S Alarm mode: sound and light alarm Heart rate alarm preset range: (exceed the preset value alarm) The upper limit is adjustable between 1-255 times/minute The lower limit is adjustable between 0-254 times/minute |
2 | NIBP |
Technology: Oscillographic Method
Measurement method: reverse measurement data is more accurate
Unit of measurement: mmHg/Kpa Overvoltage protection: double safety protection One measurement time: less than 45S Pressure range in cuff: 0-250mmHg Blood pressure measurement accuracy: ANSI/AAMI SP10-2002 standard stipulates the average error and standard deviation value Initial inflation of cuff: 180mmHg (120mmHg for children) Cuff subsequent inflation: original systolic blood pressure + 30mmHg Blood pressure measurement range and error: Systolic blood pressure 60 mmHg~250 mmHg Average pressure 45 mmHg~235 mmHg Diastolic blood pressure 40 mmHg~220 mmHg Blood pressure measurement error: ±1.1KPa (±8mmHg) or ±10%, whichever is greater Response time: 1S Alarm mode: sound and light alarm Alarm prediction range and error: (Alarm when exceeding the preset value) Systolic blood pressure upper limit 1mmHg~255 mmHg Lower limit 0 mmHg ~255 mmHg
Diastolic blood pressure upper limit 1mmHg~255 mmHg Lower limit 0 mmHg~254 mmHg Alarm error: ±1 mmHg Use standard: in line with ANSI/AAMI SP10-2002 standard |
3 | SPO2 | Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 beats/min Response time: 1S Alarm mode: sound and light alarm Alarm range and error: (Alarm exceeding the preset value) Upper limit 1%~100% Lower limit 0%~99% |
4 | TEMP | Technology: Highly sensitive thermistor probe Body temperature measurement range: 20℃-- 45℃ Resolution: 0.1% Body temperature accuracy: ±1℃ Response time: 1S Alarm mode: sound and light alarm Alarm preset range and error: (Alarm when exceeding the preset value) The upper limit is adjustable between 20.1℃-- 45.5℃ The lower limit is adjustable between 20℃ and 45.4℃ Alarm error: ±1℃ |
5 | RESP | Respiration rate range: 0-60 times/min Accuracy: ±1rpm Response time: 1S Gain options: ×1, ×2, ×4, ×0.5 four gears Alarm mode: sound and light alarm Alarm preset range and error: (Alarm when exceeding the preset value) The upper limit is adjustable between 10-100 times/minute The upper limit is adjustable between 0-99 times/minute Alarm error: ±1rpm |
6 | Printer(Optonal) | Specifications: Dual-channel thermal array recorder Printing method: real-time or event trigger recording waveform, text Resolution: Horizontal: 400dpi / Vertical: 800dpi Note: Date (year/month/day)/time (24 hours) Optional wall bracket, mobile bracket, backpack |
7 | System |
Display: 12.1 inch TFT true color LCD display Battery (optional): LeadAcid fully sealed maintenance-free battery |
Standard configuration
1 | PM-9000+ pet version host | 1 unit |
2 | Animal ECG Clip Type Cable | 1 set |
3 | Animal blood pressure cuffs | 1 set |
4 | Animal blood oxygen probe | 1 set |
5 | Body temperature probe | 1 set |
6 | Power code | 1 set |
7 | Grand wire | 1 set |
Optional Configuration
1 | Built-in rechargeable lithium battery |
2 | Two-channel thermal printer |
3 | Monitor cart/bracket/hanger |
Feature
1 | Adopting world-famous brand modules, with high precision, standard parameters, reliable quality and stable performance. |
2 | High-brightness and high-resolution 12.1-inch color TFT LCD display. |
3 | The body is light and strong, easy to carry. |
4 | Rotary shuttle operation mode, dual-purpose operation interface in Chinese and English, easy to learn, easy to use and easy to operate. |
5 | All-lead seven-channel simultaneous display of ECG. |
6 | ST segment automatic detection, arrhythmia analysis, drug concentration drop table analysis. |
7 | NIBP dual overvoltage protection temperature drift control and other technologies ensure accurate measurement and protect patient safety. |
8 | Powerful storage capacity, full-parameter trend chart data throughout the entire process, ECG waveform storage and playback, and power-off save data functions. |
9 | The upper and lower alarm limits can be set arbitrarily, with automatic sound and light double alarm. |
10 | Suitable for various mammals such as cats and dogs. |
11 | Anti-defibrillation, anti-interference of high-frequency electric knife. |
12 | Support wired and wireless networking functions, support software online upgrades. |
13 | Optional built-in removable lithium battery for both AC and DC power. |
14 | Optional built-in dual-channel thermal array recorder, real-time printing of waveforms and icons. |
15 | It is widely used in various pet clinics, pet hospitals, veterinary stations, and zoos. |
Contact Person: Mrs. Helen Bo
Tel: 86-13382885910
Fax: 86-510-85572789