Product Details:
|
Syringe Size: | 1 Ml - 20 Ml Single-use Syringe | Infusion Rate: | 1 Mm/hr - 99 Mm/hr |
---|---|---|---|
Alarms: | Battery Depleted, Mechanical Error, Occlusion, Syringe Disengaged, Completion | Alerts: | Battery Low, Syringe Not Loaded, Near End |
OLED Display: | Syringe Size; Rate Is Set By Mm/hr And Displayed In Ml./hr Simultaneously; Alarm Messages | Maximum Infusion Pressure: | ≤ 0.12MPa(with 10 Ml Syringe) |
Dimension: | 166 (L) X 60 (B) X 30 (H) Mm | Weight: | ≤ 180g (battery Weight Not Included) |
Highlight: | infusion syringe pump,infusion pumps |
1 | Syringe Size | 1 ml - 20 ml single-use syringe |
2 | Infusion Rate | 1 mm/hr - 99 mm/hr |
3 | Alarms | Battery Depleted, Mechanical Error, Occlusion Syringe Disengaged, Completion. |
4 | Alerts | Battery Low, User Prompt, Syringe Not Installed, Near End |
5 | Accuracy | ± 2 % |
6 | Bolus Volume | No limit, min. 0.1 ml |
7 | PCA Function | When the flow rate number is lower than ½ of the syringe size, P.C.A. Function can be enabled. Each bolus is ¼ of current hourly volume, with 30 min locking interval |
8 | OLED Display | Syringe size; rate is set by mm/hr and displayed in ml/hr simultaneously; alarm messages, run- ning status. |
9 | “LOW BATT” LED Indicator | Flashing yellow/red indicator when battery is low or depleted |
10 | Maximum Infusion Pressure | ≤ 0.12 MPa (with 10 ml syringe) |
11 | Occlusion Alarm Pressure | 0.12 MPa (with 10 ml syringe)CE 0197, IEC 60601 |
12 | Safety Approvals | CE 0197, IEC 60601 - 1 - 8: 2003, Type CF, IPX1 |
13 | Battery Size | AA x 3 |
14 | Dimensions | 166(W) x 60(D) x 30(H) mm |
15 | Weight | ≤ 180g (battery weight not included) |
Applications
1 | Thalassemia |
2 | Parkinson (Apokinon) etc. |
3 | Neonatal Care |
4 | Immunity Deficiency (Globulin) |
5 | Chemotherapy |
6 | Pain Management |
7 | Epidural Treatment |
Safety & Accessories
1 | Alarm Indicators | An immediate identification of pump’s alarm and alert messages. |
2 | Bolus Cable (PCA) | Patient can push Bolus button to add extra dos-age for quick relief of pain. (Maximum 1 push every 30 minutes for safety). |
3 | Bright OLED Screen | Bright & Engergy saving OLED screen displays both infusion rate and alarm message. |
4 | Carrying Bag | The carrying bag comes with programmable lock and exit for the PCA cable and IV line for patient. |
5 | Syringe Cover | Protects the syringe during the infusion to guarantee the safe & accurate infusion. |
6 | Package Contents | The complete package includes a carrying bag with programmable lock for ambulatory use, syringe covers, operating instruc- tions and a set of batteries. |
Easy of Use
1 | Lightweight and compact. |
2 | Digital programming with a bright OLED screen. |
3 | Clear display of current infusion rate and alarm message. |
4 | Powered by 3 X AA batteries |
Contact Person: Mrs. Helen Bo
Tel: 86-13382885910
Fax: 86-510-85572789